Vista de página 90
Memo-Graph S 10 Technical data
Endress+Hauser 91
Field housing IP65 field housing dimensions:
Figure 13: Field housing dimensions
Weight VDM with front in stainless steel or metal die-cast: approx. 3.5 kg / 7.72 lb
VDM built-in in desk top housing: approx. 6.4 kg / 14.1 lb
Materials Stainless steel casing
Metal die-cast version: front bezel/door in metal die-cast, abrasion-proof matt chrome coating
(colour similar to RAL 9006), protective glass screen in front of display
Stainless steel version: front bezel in stainless steel, polycarbonate plastic screen in front of display
10.8 Display and operating system
Display elements Display:
STN colour graphic display with 145 mm screen diagonals (5.7”), 76,800 pixels
(320 x 240 Pixel)
Display modes:
Curves / plot sequences, curves in zones, bargraph, digital display, event list / Audit trail (limit
values / power failures), status display, history display in curve form with display of digital measured
values, date and time; signal analysis (min., max., averages, quantities, time) channel identification
with colour display and set tag number in plain text
Signal groups:
8 groups with 8 channels (analogue, mathematically-calculated and digital inputs)
Operating elements Keyboard:
optional operation from the front using 6 operating keys in dialogue with the screen (the function
of the keys is displayed on screen).
Remote operation PC:
Remote configuration using front-mounted RS 232 serial interface (only for metal die-cast front) or
using rear-mounted RS 232 interfaces (e.g. modem) or RS 485 with PC software.
Real time clock Automatic switchable summer/normal time 4 year buffering (ambient temperature 15 to 25°C /
59 to 77°F)
Time drift: max. 25 ppm
Mathematics function Eight additional, calculated channels; can be cascaded
Mathematical combination of analogue channels, basic arithmetic operations
(+, -, *, /), constants, integration (quantity caclulation from analogue channel) and mathematical
functions: log, ln, exp, abs, sqrt, quad, sin, cos, tan, asin, acos, atan.
Formula: f = (g (y1)*a) ? (y2*b)+c
320 mm (12.6“)
320 mm (12.6 “)
254 mm (10 “)